AN3510 Vibration Monitoring Protector
AN3510 Vibration Monitoring Protector
Classification:
Product Description
Technical data
1. Sensor input:
Magnetoelectric velocity sensor: seismic passive sensor, no power supply required, signal output sensitivity: 20mV/mm/s (500mV/(in/s);
Piezoelectric accelerometer: ICP type, 24V/4mA constant current source power supply, signal output sensitivity: 10mV/(m/s2) (100 mV/g);
Proximity sensor: Φ5/Φ8 diameter probe, sensitivity: 7.87 mV/μm (200 mV/mil); GAP voltage: -10V.
2. Measuring range:
Amplitude: 0~999μm(Pk-Pk); Precision: ±0.5%±1μm;
Speed: 0~99.9mm/s (rms); Accuracy: ±0.5%±0.1 mm/s;
Acceleration: 0~9.99g(Pk); Accuracy: ±0.5%±0.01 g.
3. Frequency range:
Shell vibration: 5/10~1000Hz;
Shaft vibration: 2.5/5~1000Hz;
Swing: 0.5~200Hz (ultra-low frequency vibration).
4. Power supply:
DC power supply: 24VDC (18~36V);
AC power supply: 220VAC(165~260V)/47~63Hz;
AC power supply: 110VAC /47~63Hz;
Power consumption: less than 5W.
5. Standard signal output:
Standard current: 4~20mA (corresponding to the upper limit of full scale);
Active: Drive Load: ≤500Ω, Effective Transmission Distance: ≤300 m (1000 ft).
6. Relay output:
Two-stage threshold (Alert, Danger) programmable setting and normally open and normally closed dry contact output, the full scale range can be set, and the error is ≤0.1%;
Insulation resistance: ≥1000MΩ;
Contact capacity: 2A/30VDC, 1A/220VAC; Double Pole Double Throw (DPDT);
Alarm delay: 0.1 to 60S, default value: 0.5S;
Alarm Latching: The default is non-latching.
7. Physical characteristics:
Dimensions (LxWxH): 120mm×70mm×80mm;
Weight: 0.8Kg.
8. Installation:
Standard rail mounting: DIN 35mm;
4-hole base plate mounting: 100mm×80mm.
9. Environmental restrictions:
Operating temperature: -30°C~+65°C;
Storage temperature: -40°C~+85°C;
Relative humidity: 0~95% non-condensing.
10. Refer to the implementation standards
American Petroleum Institute API 670 standard;
Safety Certification: C E;
Degree of protection: IP65;
Immunity to electromagnetic interference: EMC\LVD with reference to EN55011\EN 61010\EN50081\EN50082.
Product selection
AN3511/12/13—Shell vibration/shaft vibration/swing
AN3511- AXX-BXX-CXX-DXX-EXX-FXX
AN3512- AXX-BXX-CXX-DXX-EXX-FXX
AN3513- AXX-BXX-CXX-DXX-EXX-FXX
Standard Models:
Shell vibration: AN3511-00-00-00-00-00-00-00
Shaft vibration: AN3512-00-01-00-00-00-00
Pendulum: AN3513-00-01-00-00-00-00
A: Measuring range:
00—Amplitude: 0~999μm(Pk-Pk)
01—Speed: 0~99.9mm/s(rms)
02—Acceleration: 0~9.99g (Pk)
B: External sensor type:
00—Magnetoelectric speed sensor
01—Proximity current sensor (φ8 or φ5 diameter probe)
02—Ultra-low frequency magnetoelectric speed sensor
03—Ultra-low frequency magnetoelectric displacement sensor
04—Piezoelectric accelerometer
05—Piezoelectric speed sensor
C: Relay output (DPDT):
00—Two dry contact outputs (Alert, Danger)
01—Single Dry Contact Output (Alert)
02—No relay output
D: Standard Signal Output:
00—4~20mA standard current output
01—1~5V standard voltage output
02—RS 485 communication interface output
E: Power supply
00—24VDC(18~36V)
01—220VAC
02—110VAC
03—Others
F: Installation
00—DIN 35mm for rail mounting
01—bottom plate installation
Note: If you choose other options, please note that you should explain, if you have any questions, please consult the company's technical support department.