AN3580 Dual-Channel Vibrometer
AN3580 Dual-Channel Vibrometer
Classification:
Product Description
Technical data
1. Sensor input:
Magnetoelectric velocity sensor: seismic passive sensor, no power supply required, signal output sensitivity: 20mV/mm/s (500mV/(in/s);
Piezoelectric accelerometer: ICP type, 24V/4mA constant current source power supply, signal output sensitivity: 10mV/(m/s2) (100 mV/g);
Proximity sensor: Φ5/Φ8 diameter probe, sensitivity: 7.87mV/μm (200 mV/mil); GAP voltage: -10V.
2. Measuring range:
Amplitude: 0~999μm(Pk-Pk); Precision: ±0.5%±1μm;
Speed: 0~99.9mm/s (rms); Accuracy: ±0.5%±0.1 mm/s;
Acceleration: 0~9.99g (Pk); Accuracy: ±0.5%±0.01 g.
Note: The measuring range can be programmed on site.
3. Frequency range:
Swing: 1~100Hz; (Low Frequency Vibration)
Shell vibration: 5/10~1000Hz;
Shaft vibration: 2.5/5~1000Hz.
4. Power supply:
DC power supply: 24VDC (18~36V);
AC power supply: 220VAC(165~260)/47~63Hz;
AC power supply: 110VAC /47~63Hz;
Power consumption: 5W.
5. Standard signal output:
Standard current: 4~20mA (corresponding to the upper limit of full scale)
Active: Drive Load: ≤500Ω Effective Transmission Distance: ≤ 300 m (1000 ft).
6. Relay output:
Programmable setting of two-level thresholds (Alert, Danger) and normally open and normally closed dry contact output for each channel, the full scale range can be set, and the error is ≤0.1%;
Insulation resistance: ≥1000MΩ;
Contact capacity: 2A/30VDC, Double Pole Double Throw (DPDT);
Alarm delay: 0.1 to 60S, default value: 0.5S;
Alarm Latching: The default is non-latching.
7. Physical characteristics:
Dimensions(WxHxD): 160mm×80mm×115mm;
Cutout size: 152mm×76mm (width x height);
Weight: 1.2Kg;
8. Installation:
Standard perforated disc mounting.
9. Environmental restrictions:
Operating temperature: -30°C~+65°C;
Storage temperature: -40°C~+85°C;
Relative humidity: 0~95% non-condensing.
10. Refer to the implementation standards
American Petroleum Institute API 670 standard;
Safety Certification: C E;
Degree of protection: IP56;
Immunity to electromagnetic interference: EMC\LVD with reference to EN55011\EN 61010\EN50081\EN50082.
Product selection
AN3581/82/83—Shell vibration/shaft vibration/swing
AN3581- AXX-BXX-CXX-DXX-EXX
AN3582- AXX-BXX-CXX-DXX-EXX
AN3583- AXX-BXX-CXX-DXX-EXX
Standard Models:
Shell vibration: AN3581-00-00-00-00-00-00-00
Shaft vibration: AN3582-00-01-00-00-00-00
Pendulum: AN3583-00-01-00-00-00-00-00
A: Measuring range:
00—Amplitude: 0~999μm(Pk-Pk)
01—Speed: 0~99.9mm/s(rms)
02—Acceleration: 0~9.99g (Pk)
03—Others
B: External sensor type:
00—Magnetoelectric speed sensor
01—Proximity current sensor (φ8 or φ5 diameter probe)
02—Ultra-low frequency magnetoelectric speed sensor
03—Piezoelectric accelerometer
04—The same type of sensor from other manufacturers
C: Relay output per channel (DPDT):
00—Two dry contact outputs (Alert, Danger)
01—Single Dry Contact Output (Alert)
02—No relay output
D: Standard Signal Output:
00—4~20mA standard current output
01—1~5V standard voltage output
02—RS 485 communication interface output
03—Others
E: Power supply:
00—220VAC
01—24VDC
02—110VAC
03—Others
Note: If you select other options for the model option, please note the description. For details, please contact the company's technical department.