AN3590 Electronic Vibration Switch
AN3590 Electronic Vibration Switch
Classification:
Product Description
Technical data
1. Measuring range:
Amplitude: 0~999μm(Pk-Pk); Precision: ±0.5%±1μm;
Speed: 0~99.9mm/s (rms); Accuracy: ±0.5%±0.1 mm/s;
Acceleration: 0~9.99g(Pk); Precision: ±0.5%±0.01 g;
Frequency range: 1~10KHz.
2. Frequency range:
Piezoelectric acceleration/speed: 1~10KHz (-3dB).
3. Power supply:
DC power supply: 24VDC (18~36V);
AC power supply: 220VAC(165~260)/47~63Hz;
AC power supply: 110VAC /47~63Hz;
Power consumption: 5W.
4. Standard signal output:
Standard current: 4~20mA (corresponding to the upper limit of full scale)
Active: Drive Load: ≤500Ω Effective Transmission Distance: ≤ 300 m (1000 ft).
5. Relay output:
Two-stage threshold (Alert, Danger) programmable setting and normally open and normally closed dry contact output, the full scale range can be set, and the error is ≤0.1%;
Insulation resistance: ≥1000MΩ;
Contact capacity: 2A/30VDC, Double Pole Double Throw (DPDT);
Alarm delay: 0.1 to 60S, default value: 0.5S;
Alarm Latching: The default is non-latching.
6. Physical characteristics:
Dimensions: 122mm×150mm×85mm;
Weight: 1.2Kg.
7. Installation:
Base plate mounting: 4 M6 screws fixed;
Installation size: 106mm×82mm.
8. Environmental restrictions:
Operating temperature: -30°C~+65°C;
Storage temperature: -40°C~+85°C;
Relative humidity: 95% non-condensing.
9. Protection level: IP65
10. Explosion-proof grade: ATEX: II2G ExdIICT4
11. Refer to the implementation standards
American Petroleum Institute API 670 standard;
Safety Certification: C E;
Degree of protection: IP65;
Explosion-proof grade: ATEX: II.2G ExdII.CT4
Immunity to electromagnetic interference: EMC\LVD with reference to EN55011\EN 61010\EN50081\EN50082.
Product selection
AN3590-AXX-BXX-CXX-DXX-EXX-FXX
Standard Models:
AN3590-01-00-00-00-00-00
A: Measuring range:
00—Amplitude: 0~999μm(Pk-Pk)
01—Speed: 0~99.9mm/s (rms)
02—Acceleration: 0~9.99g (Pk)
XX—Others (remarks)
Note: The range can be programmed on site.
B: Sensor type
00—Built-in piezoelectric accelerometer
01—Built-in piezoelectric velocity sensor
C: Relay output (DPDT)
00—Single Dry Contact Output (Alert)
01—Two dry contact outputs (Alert, Danger)
02—No relay output
D: Standard signal output, remote transmission host computer
00—4~20mA standard current output
01—No output
E: Power supply
00—24VDC(18~36V)
01—220VAC
02—Others
F: Approving Body
00—No requirement
01—explosion-proof
Note: If you select other options for the model option, please note the description. For details, please contact the company's technical department.
Previous Page